API · ASME · DIN · EN standard industrial valves

Dual Plate Check Valves

Dual plate check valves carry two spring-loaded semicircular plates on a centre hinge, so the plates close over a short travel while flow is still decelerating — the usual answer where slam and water hammer must stay low in a compact wafer body. The range covers a wafer series at DN50 to DN900, Class 150 to Class 2500, with ductile iron, stainless and aluminium bronze discs, stainless spring and stem, and elastomer-to-stainless seats (EPDM, NBR, Viton, CF8, CF8M). Face-to-face follows API 594 / ASME B16.10 and testing runs to API 598. Selection turns on the wafer length against the mating flanges, seat material versus temperature and medium, and the spring characteristic against the expected reversal.

Part of the Check Valves family

Last updated: 2026-11

Family specifications

size range DN50 to DN900
pressure class Class 150 to Class 2500
body materials Cast Iron, Ductile Iron, Cast Steel, Stainless Steel, Aluminium Bronze
disc materials Ductile Iron, Stainless Steel, Aluminium Bronze
seat materials EPDM, NBR, VITON, CF8, CF8M
end connections Wafer
operation Self-acting (automatic)
temperature range -196°C to 570°C
design standards API 594
testing standards API 598
face to face API 594, ASME B16.10
spring material Stainless Steel
kDp product name API 594 Dual Plate Check Valve
kDp type Wafer Check Valve
kDp design standard API 594
kDp body material ASTM A351 CF8M
kDp example size 4 Inch, DN100
kDp example pressure Class 150 LB, PN20
kDp end connection Wafer Ends
kDp size range NPS 2–60 Inch (DN50–DN1500)
kDp temperature range -29°C to 595°C
kDp pressure range Class 150–2500 (PN10–PN420)
kDp material options ASTM A216 WCB, WCC, A217 WC6, WC9, C5, C12A, A352 LCB, LCC, A351 CF8, CF8M, CF3M, CF8C
kDp end connections Wafer, Lug, Clamp, Flanged
kDp design manufacture standards API 594, API 6D, JB/T 8937
kDp face to face API 594, API 6D, JB/T 8937, DIN 3202
kDp flange standards ANSI B16.5, DIN 2543–48, JB/T 9112–24
kDp butt weld standard ANSI B16.25
kDp testing standards API 598, DIN 3230, JB/T 9092
kDp service media Water, gas, oil, etc.
kDp disc open angle Discs open 85° to ensure a low pressure drop
kDp sealing design Zero Leakage Sealing Design with Soft Seated
kDp non slam design Non Slam Design
kDp bubble tight Bubble Tight Closed Off
kDp structure unique center vertical pin shaft design
wDp example size 6 Inch
wDp example pressure Class 150
wDp body bonnet material ASTM A216 WCB
wDp end connection Wafer
wDp design standard ASME B16.34
wDp face to face ASME B16.10
wDp testing standard API 598
lDp design standard API 594
lDp body material ASTM A890 4A
lDp disc material ASTM A890 4A
lDp spring material nickel-chromium alloy X-750
lDp example pressure 150#
lDp example size 30 Inch

Ordering & documentation

Documents

Ask for the documentation set with the inquiry — typical items (material certificates, test reports to the listed inspection standard, dimensional drawings) are confirmed and supplied with the quotation.

Quotation

Send the medium, temperature, pressure, size and connection for a quotation-ready inquiry. Lead time, MOQ and price are confirmed at quotation, together with the documents to be supplied with the order.

Sample & supply

Supply terms, order quantities and lead time are agreed per order — state the destination country and required schedule with the inquiry.

Storage & shipping

Store valves with seats and seals protected from UV, ozone and deformation, and keep end-face protectors on until installation; storage limits and shipping arrangements for the selected materials are confirmed at quotation.

Frequently asked questions

What standards govern the design and testing of dual plate check valves?

The published specification for this family lists API 594 as the design standards. Testing follows API 598.

What sizes and pressure ratings are available for dual plate check valves?

The published size range is DN50 to DN900, and the published pressure ratings are Class 150 to Class 2500. Availability of a specific size and rating is confirmed at quotation.

What materials are dual plate check valves available in?

The published specification lists body materials: Cast Iron, Ductile Iron, Cast Steel, Stainless Steel, Aluminium Bronze. Material availability for a specific size and rating is confirmed at quotation.

What working temperature range do dual plate check valves cover?

The published working temperature range is -196°C to 570°C. For a medium at the edge of the range, confirm the suitability of the selected seat and body materials at quotation.

What end connections do dual plate check valves support?

The published specification lists Wafer as the available end connections. The connection for a specific size is confirmed at quotation.

What should a quotation inquiry for dual plate check valves include?

The governing standard and class, nominal size, body and seat materials, the service medium with temperature, and the destination — anything missing is confirmed during quotation.

Request a quote for dual plate check valves

Submit the requirement here — a quotation-ready inquiry states the governing standard and class, size, materials, medium, temperature and destination.

What happens to your details is described in our privacy notice.

Get a quotation for Dual Plate Check Valves

Send the standard, pressure class and size for a quotation-ready inquiry — answered with documents and terms.